E5515C Configuration
- Turn the phone off.
- Make sure the MOB-IP-SIM unit is ON.
- Turn on the E5515C Test Set.
- On the E5515C/E6702A, select the System Config screen.
- Select F1 Instrument Setup.
- Highlight the IP Address setting; enter the simulator's address,
then highlight Subnet Mask and
enter 255.255.0.0; leave the Default Gateway
blank (enter a 0 to make it blank).
- Press F6 Close Menu.

- Select the Call Setup screen
- Select the FCH Service Option Setup screen
- Select SO33

- Press F8 to select the proper Cell Band and F9 to select the
proper Channel for the phone.

- On the left-hand side of the display, press the More button
for screen 2 of 3
- Press F2 Cell Info
- Press F2 Cell Parameters

- Select System ID and change SID to match the phone (typically
2). Sanyo 4900 uses SID = 4274.
- Press F4 Registration Parameters
- Change the Timer Based Registration State to Off.
- Press F6 two times to close the popup menu and return.

- Use the E5515C front panel menu to navigate to the Use External
PDSN menu and enable the External PDSN:
- Set the External PDSN address to the MOB-IP-SIM's
static IP
address.
- Set the ICP Port to 53613.
- Set the External PDSN to ON.
- The E5515C should indicate that the link is established with
the MOB-IP-SIM after entering all the external PDSN
parameters.
- Exit back to the E5515C call processing menu.