| CSP-5850 Script Package for Agilent E5515C and MIP-5850: User Manual | ||
|---|---|---|
| Prev | Chapter 3. Configuration | Next |
The Agilent E5515C needs to be configured with a static IP address, a GPIB address, and the IP address for the MIP-5850.
The GPIB address programmed into the Agilent E5515C must match the GPIB address in "config.py". The default (example) config.py uses 14 as the GPIB address of the Agilent E5515C. To set the Agilent E5515C GPIB Address, first select "System Config" button (found in the "Screens" box on the front panel). Then, on the left hand side of the screen, you should see "Instrument Setup" (F1 key). Select that, and the window open has the settings for GPIB Address, LAN (ethernet) IP Address, Subnet Mask, and UTC Date/Time.
Mobile IP typically uses cdma2000 Service Option 33 for data calls. All the normal data call setup parameters on the E5515C apply to mobile IP and are not covered in this manual. The E5515C configuration does need to include setting the External PDSN IP Address of the MIP-5850 unit. If the MIP-5850 is configured to use DHCP to allocate an address, you can use the AT command "at+ipdhcpaddr?" to query its IP address from its serial port. The E5515C is also assumed to be set up and ready to handle standard data calls.
This completes the E5515C setup.