This chapter defines the scripts supported and general information to assist in running them. A few items are worth noting:
Test section 3 covers Simple IP data call originations. The wirless device must be set to originate the data call in Simple IP mode. This may be accomplished by sending the wireless device an AT$QCMIP=0 command. The user's device may require a different method.
Test section 4 covers Mobile IP agent discovery and registratioin. The wirless device must be set to originate the data call in Mobile IP mode. This may be accomplished by sending the wireless device an AT$QCMIP=2 command. The user's device may require a different method.
Test sections 5.1-5.4 cover Mobile IP inter and intra PDSN handoff. The wirless device must be set to originate the data call in Mobile IP mode. This may be accomplished by sending the wireless device an AT$QCMIP=2 command. The user's device may require a different method.
Test sections 5.5-5.6 cover Simple IP inter and intra PDSN handoff. The wirless device must be set to originate the data call in Simple IP mode. This may be accomplished by sending the wireless device an AT$QCMIP=0 command. The user's device may require a different method.
Test section 6.4 covers mobile response to Authenication Failure
This test verifies the proper operation of Simple IP with CHAP authentication. This test verifies the mobile station can terminate the PPP session. The wirless device must be set to originate the data call in Simple IP mode.