3.1.8. E5515C Configuration

Mobile IP typically uses service option 33 for data calls. All the normal data call setup parameters on the E5515C apply to mobile IP and are not covered in this manual. The E5515C configuration and connection required to link it to the MOB-IP-SIM™ are explained here, but the Mobile IP wireless device setup and MOB-IP-SIM™ configuration are assumed to been completed as described in Chapter 3, Simulator Configuration . The E5515C is also assumed to be set up and ready to handle standard SO33 data calls.

  1. Connect the required communications test set, PCs, Hubs, phone, and MOB-IP-SIM™ as diagrammed in Appendix D, E5515C Interconnection .

  2. Make sure power is applied to all devices and that the required power-up operations are complete.

  3. Use the E5515C soft menu to navigate to the Data Channel Parameters menu and set the external PDSN address to the MOB-IP-SIM™ local address previously recorded in section [B] of Appendix E, Simulator Configuration Worksheet and set the External PSDN State to ON.

  4. The E5515C should indicate that the link to the MOB-IP-SIM™ is active after entering the external PDSN address.

  5. Exit back to the E5515C call processing menu.

This completes the E5515C set up.