This chapter will tell you:
How to confirm you that have all the components of the MOB-IP-SIM
What additional components you are required to supply
How to connect the MOB-IP-SIM to your RF test set
How to install the MOB-IP-SIM Manager configuration utility
Carefully unpack your MOB-IP-SIM and inspect for any damage. You should have one each of the following:
Main MOB-IP-SIM unit (Either MIP-5800 or MIP-5850 )
DE-9 to DE-9 null-modem serial cable
Category 5 10BaseT cable for connecting the MOB-IP-SIM to the LAN
External 12VDC power supply
MOB-IP-SIM CD-ROM
This manual
You are expected to provide the following items:
Agilent E5515C RF Test Set(s) with the E6702B cdma2000 lab application software and/or the E6706A 1xEV-DO lab application software
A Windows PC with free serial and Ethernet ports
There is no need to open the MOB-IP-SIM enclosure since all configuration is done using software interfaces.
Since the MOB-IP-SIM is a feature extension product designed to be used with the Agilent E5515C, installation and operation will require reference to the Agilent documentation for those procedures outside the scope of this document.
After reviewing the connection diagram in Appendix D, install the MOB-IP-SIM Manager setup utility found on the accompanying CD-ROM by running setup.exe located in the MobIpSimManager folder.
Open the MOB-IP-SIM Manager from your PC by using the Windows Start menu. When the Options screen appears, click on the button and follow the instructions to configure the LAN parameters. The manager will instruct you to power-on the unit, connect cables, etc. at the appropriate time. When the setup is complete, the MOB-IP-SIM will have been assigned a specific IP address. Record the MOB-IP-SIM IP address in section [B] of Appendix E.
The IP address may be set without the MOB-IP-SIM Manager by following the procedure in Appendix F.
Note: Do not connect anything until so instructed by the MOB-IP-SIM Manager software.